BarriAire™ Gold Hood Complete Coverage (STK) 3979471
Particulate coverage includes entire head except for Sure‑Fit™ panel at crown. Front and back bib extends particualte barrier coverage beyond critical areas as identified by NFPA – Maximum Protection. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition. Certification to the NFPA 1971, 2018 Edition Option for Particulate Protection – Current Edition. EN13911: 2017 Certification Pending.
Fabric Description:Quilted composite durable water resistant finish on exterior layer of jersey knit with Nomex® Nano Flex particulate barrier between the inside layer of jersey knit. Averages 95%‑98% particulate filtration efficiency that actually improves with repeated launderings.
Test Results:Fabric Performance ValuesRequirements NFPA 1971
2018 EditionPGI Test ResultsParticulate Efficiency≥ 90%96%Thermal Protective Performance (TPP)Rib Knit
- As Received
- 20.0 (min)30.2After 5 Washings
20.0 (min)33.1Quilted Composite
- As Received
- 20.0 (min)29.3After 5 Washings
20.0 (min)30.8Total Heat Loss (THL)≥ 325 W/m2401.3 W/m2Hood Material Burst Strength> 225 N614 NFlame Resistance Test – Quilted CompositeAfter Flame (Wales x Courses)
- As Received
- ≤ 2.0 sec0.0 sec x 1.0 secAfter 5 Washings
≤ 2.0 sec1.0 sec x 1.0 secChar Length (Wales x Courses)
- As Received
- ≤ 100 mm18 mm x 17 mmAfter 5 Washings
≤ 100 mm3 mm x 2 mmCleaning Shrinkage Resistance TestHood Measurement
- After 5 Washings
≥ -5%-0.3%Face Opening Measurement
- After 5 Washings
Meets RequirementYESHeat & Thermal Shrinkage Resistance TestHood Measurement
- As Received
- ≥ -10%0%After 5 Washings
≥ -10%0%Face Opening Measurement
- As Received
- Meets RequirementYESAfter 5 Washings
- Meets RequirementYESSeam Breaking Strength TestQuilted to Quilted
- > 181 N1219 NQuilted to Knit
> 181 N1144 NMelt or Drip When Exposed to FlameNo Melting or DrippingNONE