BarriAire™ Gold Hood Critical Coverage (STK) 3979471-1
Particulate coverage from base of the neck and around entire head except for Sure‑Fit™ panel at crown. All critical areas of particualte penetration as identified by NFPA have particulate barrier. UL Classified to NFPA 1971 Standard on Protective Ensembles for Structural Fire Fighting and Proximity Fire Fighting – Current Edition. Certification to the NFPA 1971, 2018 Edition Option for Particulate Protection – Current Edition. EN13911: 2017 Certification Pending.
Fabric Description:Quilted composite durable water resistant finish on exterior layer of jersey knit with Nomex® Nano Flex particulate barrier between the inside layer of jersey knit. Averages 95%‑98% particulate filtration efficiency that actually improves with repeated launderings.
Test Results:
Fabric Performance ValuesRequirements NFPA 1971
2018 EditionPGI Test ResultsParticulate Efficiency≥ 90%96%Thermal Protective Performance (TPP)Rib Knit
- As Received
- 20.0 (min)30.2After 5 Washings
20.0 (min)33.1Quilted Composite
- As Received
- 20.0 (min)29.3After 5 Washings
20.0 (min)30.8Total Heat Loss (THL)≥ 325 W/m2401.3 W/m2Hood Material Burst Strength> 225 N614 NFlame Resistance Test – Quilted CompositeAfter Flame (Wales x Courses)
- As Received
- ≤ 2.0 sec0.0 sec x 1.0 secAfter 5 Washings
≤ 2.0 sec1.0 sec x 1.0 secChar Length (Wales x Courses)
- As Received
- ≤ 100 mm18 mm x 17 mmAfter 5 Washings
≤ 100 mm3 mm x 2 mmCleaning Shrinkage Resistance TestHood Measurement
- After 5 Washings
≥ -5%-0.7%Face Opening Measurement
- After 5 Washings
Meets RequirementYESHeat & Thermal Shrinkage Resistance TestHood Measurement
- As Received
- ≥ -10%0%After 5 Washings
≥ -10%0%Face Opening Measurement
- As Received
- Meets RequirementYESAfter 5 Washings
- Meets RequirementYESSeam Breaking Strength TestQuilted to Quilted
- > 181 N1219 NQuilted to Knit
> 181 N1144 NMelt or Drip When Exposed to FlameNo Melting or DrippingNONE
BarriAire Gold Hoods feature an ultra‑light weight inner layer of DuPont™ Nomex® Nano Flex fabric. This innovative particulate barrier blocks 95% of harmful contaminants and potentially carcinogenic particulates .20 microns in size or larger.
FAST UV-light photographs without Nomex® Nano Flex (left) and with Nomex® Nano Flex (right) illustrating after particle exposure for the test subject’s head and neck; bright yellow areas show where particles penetrated the ensemble.
Above test performed on complete coverage hood without turnout coat. Test was performed at RTI (Test #2322, DOD Test Operations Procedure 10‑2‑022 modified for head form). These conditions may not be typical of the conditions encountered in actual situations. The results of these tests are only predictions under these specific laboratory conditions. The user is solely responsible for any interpretations of the test data provided by DuPont. DUPONT MAKES NO WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE AND ASSUMES NO LIABILITY IN CONNECTION WITH ANY USE OF THIS INFORMATION. This data is not intended for use by the user or others without expressed written consent of DuPont. DuPont and Nomex are trademarks or registered trademarks of E.I. du Pont de Nemours and Company or its affiliates.